KCM FILTER
Metal and GFPP duplex bag filter housings in parallel manifold and valved changeover configurations
Duplex housing configurations

Valved Changeover Configuration

KCM-DB Valved Duplex Bag Filter Housings

KCM-DB valved duplex bag filter housings maintain filtration through one vessel while the other is isolated for bag replacement. The 14 configurations include 10 metal and 4 GFPP assemblies, with one bag per vessel.

  • Bag sizes · Size #1 or #2, depending on the model
  • Housing materials · Carbon steel, 304 or 316 stainless steel, or glass reinforced PP
  • Connections · 2" NPT; 2" (DN50), 3" (DN80) or 4" (DN100) flanges
  • Seal materials · Buna-N, EPDM or FKM

Selection Overview

Size one operating vessel for 100% of the process flow during changeover. Select bag size, valve arrangement and seal compound for the liquid, viscosity and solids loading.

Allow clearance for cover opening, bag and basket removal, and valve operation. Allowable pressure depends on operating temperature and the supplied components.

Bag Size
#1 and #2
Housing Material
Carbon Steel, 304 Stainless Steel, 316 Stainless Steel, Glass reinforced PP
Connections
2" NPT; 2" (DN50), 3" (DN80) or 4" (DN100) flanges
Seal Material
Buna-N, EPDM or FKM

Series Catalog

Browse KCM-DB Valved Models

Search by KCM model number or a listed Hayward Flow Control part number. View all 23 KCM-DB models.

14 Products

KCM-DB-CS-0005 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-CS-0005

View Product

Carbon Steel valved duplex bag filter housing for size #2 filter bags with a 2" Flange connection and a Buna seal.

Material
Carbon Steel
Pipe Size
2" Flange
Seal Material
Buna
Inlet/Outlet Style
Side In, Side Out
KCM-DB-GPP-0001 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-GPP-0001

View Product

OEM Reference · Hayward Flow Control FLV4P1D20F2VS

Glass reinforced PP valved duplex bag filter housing for size #1 filter bags with a 2" Flange connection and a FKM seal.

Material
Glass reinforced PP
Pipe Size
2" Flange
Seal Material
FKM
Inlet/Outlet Style
Front In, Front Out
KCM-DB-GPP-0002 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-GPP-0002

View Product

OEM Reference · Hayward Flow Control FLV4P2D30F2VS

Glass reinforced PP valved duplex bag filter housing for size #2 filter bags with a 3" Flange connection and a FKM seal.

Material
Glass reinforced PP
Pipe Size
3" Flange
Seal Material
FKM
Inlet/Outlet Style
Front In, Front Out
KCM-DB-GPP-0003 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-GPP-0003

View Product

OEM Reference · Hayward Flow Control FLV4P2D40F2VS

Glass reinforced PP valved duplex bag filter housing for size #2 filter bags with a 4" Flange connection and a FKM seal.

Material
Glass reinforced PP
Pipe Size
4" Flange
Seal Material
FKM
Inlet/Outlet Style
Front In, Front Out
KCM-DB-S304-0003 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S304-0003

View Product

304 Stainless Steel valved duplex bag filter housing for size #1 filter bags with a 2" NPT connection and a Buna seal.

Material
304 Stainless Steel
Pipe Size
2" NPT
Seal Material
Buna
Inlet/Outlet Style
Side In, Side Out
KCM-DB-S304-0004 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S304-0004

View Product

304 Stainless Steel valved duplex bag filter housing for size #1 filter bags with a 4" Flange connection and a Buna seal.

Material
304 Stainless Steel
Pipe Size
4" Flange
Seal Material
Buna
Inlet/Outlet Style
90 Degree Elbow
KCM-DB-S304-0005 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S304-0005

View Product

304 Stainless Steel valved duplex bag filter housing for size #2 filter bags with a 2" Flange connection and a Buna seal.

Material
304 Stainless Steel
Pipe Size
2" Flange
Seal Material
Buna
Inlet/Outlet Style
Side In, Side Out
KCM-DB-S304-0006 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S304-0006

View Product

304 Stainless Steel valved duplex bag filter housing for size #2 filter bags with a 2" NPT connection and a Buna seal.

Material
304 Stainless Steel
Pipe Size
2" NPT
Seal Material
Buna
Inlet/Outlet Style
Side In, Side Out
KCM-DB-S304-0007 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S304-0007

View Product

304 Stainless Steel valved duplex bag filter housing for size #2 filter bags with a 3" Flange connection and a Buna seal.

Material
304 Stainless Steel
Pipe Size
3" Flange
Seal Material
Buna
Inlet/Outlet Style
Side In, Side Out
KCM-DB-S304-0008 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S304-0008

View Product

304 Stainless Steel valved duplex bag filter housing for size #2 filter bags with a 4" Flange connection and a Buna seal.

Material
304 Stainless Steel
Pipe Size
4" Flange
Seal Material
Buna
Inlet/Outlet Style
90 Degree Elbow
KCM-DB-S316-0002 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S316-0002

View Product

316 Stainless Steel valved duplex bag filter housing for size #2 filter bags with a 2" Flange connection and a Buna seal.

Material
316 Stainless Steel
Pipe Size
2" Flange
Seal Material
Buna
Inlet/Outlet Style
Side In, Side Out
KCM-DB-S316-0003 Valved Duplex Bag Filter Housing

Valved Duplex Bag Filter Housing

KCM-DB-S316-0003

View Product

316 Stainless Steel valved duplex bag filter housing for size #2 filter bags with a 2" Flange connection and a EPDM seal.

Material
316 Stainless Steel
Pipe Size
2" Flange
Seal Material
EPDM
Inlet/Outlet Style
Side In, Side Out

Cross-Reference Guide

OEM BrandOEM ModelKCM ModelKey Spec Notes
Hayward Flow ControlFLV4P2D20F2VSKCM-DB-UN-0001Glass reinforced PP vessels, one #2 bag per vessel, 2 in. CPVC flanges and three-way changeover valves.
Hayward Flow ControlFLV4P1D20F2VSKCM-DB-GPP-0001Glass reinforced PP vessels, one #1 bag per vessel, 2 in. CPVC flanges and three-way changeover valves.
Hayward Flow ControlFLV4P2D30F2VSKCM-DB-GPP-0002Glass reinforced PP vessels, one #2 bag per vessel, 3 in. CPVC flanges and three-way changeover valves.
Hayward Flow ControlFLV4P2D40F2VSKCM-DB-GPP-0003Glass reinforced PP vessels, one #2 bag per vessel, 4 in. CPVC flanges and three-way changeover valves.

Parallel Manifold or Valved Changeover?

The KCM-DB range contains 9 parallel manifold assemblies and 14 valved changeover assemblies. Each assembly has two vessels and one filter bag per vessel.

Comparison of the three KCM-DB configuration groups
ConfigurationModelsMaterials / Bag SizeOperating Duty
Parallel Manifold9Aluminum, carbon steel, 304 / 316 SS; Size #2Two vessels share flow. Changeover valves and isolation piping are separate.
Metal Valved Changeover10Carbon steel, 304 / 316 SS; Size #1 or #2One vessel carries full process flow while the other is isolated for service.
GFPP Valved Changeover4GFPP vessels, CPVC flanged connectors, FKM seals; Size #1 or #2Linked three-way valves select the operating vessel.

Continuous filtration during bag change-out

Size the valved assembly for 100% of the process flow through one operating vessel. Isolate, depressurize and drain the idle vessel before opening it.

Vessel A in service
InletOutletABIn serviceIsolated
Vessel B in service
InletOutletABIn serviceIsolated

Functional flow states; diagrams do not specify valve-handle positions. Vent, drain and any pressure-balancing connections follow the supplied assembly drawing.

Pressure & Flow Reference

Metal pressure classes and housing-only flow references
Metal ConfigurationPressure ClassHousing-Only Flow Reference
Parallel Manifold / 9 models150 psi (10.3 bar)Up to 440 US gpm (99.9 m³/h), both vessels operating
Flanged Valved Changeover / 7 models150 psi (10.3 bar)Up to 220 US gpm (50.0 m³/h) per operating vessel
NPT Valved Changeover / 3 models150 psi (10.3 bar)Model-specific hydraulic selection

Metal pressure classes identify the listed configurations. Allowable pressure at operating temperature depends on the vessel, seals and valves. The 440 / 220 US gpm values are housing-only family references, not installed-bag duty ratings.

GFPP vessels with CPVC manifolds

GFPP pressure-temperature rating and maximum flow by model
KCM ModelConnectionReference Pressure / TemperatureListed Maximum Flow
KCM-DB-GPP-00012" (DN50) Flange150 psi (10.3 bar) at 70°F (21°C)100 US gpm (22.7 m³/h)
KCM-DB-GPP-00023" (DN80) Flange150 psi (10.3 bar) at 70°F (21°C)150 US gpm (34.1 m³/h)
KCM-DB-GPP-00034" (DN100) Flange150 psi (10.3 bar) at 70°F (21°C)150 US gpm (34.1 m³/h)
KCM-DB-UN-00012" (DN50) Flange150 psi (10.3 bar) at 70°F (21°C)100 US gpm (22.7 m³/h)

GFPP data apply to non-shock liquid service; allowable pressure decreases with temperature. Pipe size, bag media, viscosity and solids loading affect flow and pressure loss. Vessel pressure rating is not the bag change-out differential pressure.

Valved Changeover Model Selection Table

14 valved changeover assemblies. Select a model for its full specifications and inquiry options.

14 KCM-DB models with configuration, bag size, housing material, process connection and seal
KCM Part NumberPipingBag SizeHousingProcess ConnectionSeal
KCM-DB-CS-0005Valved#2Carbon Steel2" (DN50) FlangeBuna-N
KCM-DB-S304-0003Valved#1304 SS2" NPTBuna-N
KCM-DB-S304-0004Valved#1304 SS4" (DN100) FlangeBuna-N
KCM-DB-S304-0005Valved#2304 SS2" (DN50) FlangeBuna-N
KCM-DB-S304-0006Valved#2304 SS2" NPTBuna-N
KCM-DB-S304-0007Valved#2304 SS3" (DN80) FlangeBuna-N
KCM-DB-S304-0008Valved#2304 SS4" (DN100) FlangeBuna-N
KCM-DB-S316-0002Valved#2316 SS2" (DN50) FlangeBuna-N
KCM-DB-S316-0003Valved#2316 SS2" (DN50) FlangeEPDM
KCM-DB-S316-0004Valved#2316 SS2" NPTBuna-N
KCM-DB-GPP-0001Valved#1GFPP2" (DN50) FlangeFKM
KCM-DB-GPP-0002Valved#2GFPP3" (DN80) FlangeFKM
KCM-DB-GPP-0003Valved#2GFPP4" (DN100) FlangeFKM
KCM-DB-UN-0001Valved#2GFPP2" (DN50) FlangeFKM

NPT identifies the thread form. Inch / DN pairs identify nominal flange sizes; flange drilling and facing follow the ordered connection. NBR (Buna-N), EPDM and FKM seals are listed by model.

View all 23 KCM-DB duplex models →

Duplex Bag Filter Housing FAQs

What is the difference between Parallel Manifold and Valved Changeover duplex housings?

Parallel Manifold assemblies share flow between two vessels for higher filtration capacity. Valved Changeover assemblies keep one vessel filtering while the other is isolated for bag replacement. The nine parallel models require separate changeover and isolation piping for online bag change-out.

How do I size a KCM-DB changeover duplex filter housing?

Size one operating vessel for 100% of the normal and peak process flow. Do not add both vessel capacities for changeover duty. Bag media, viscosity, solids loading, valve losses and allowable pressure at operating temperature determine the usable flow.

What materials and bag sizes are available in the KCM-DB series?

Materials include aluminum, carbon steel, 304 SS, 316 SS and GFPP. Parallel Manifold models use Size #2 bags; metal and GFPP Valved Changeover models include Size #1 and Size #2. Each assembly has two vessels with one bag per vessel. Connections and seals are listed by model.

Can the idle vessel be opened while the other vessel is filtering?

The idle vessel can be opened only after isolation, depressurizing and draining as described in the supplied instructions. The other vessel must carry the full process flow. Valve positions and vent, drain or pressure-balancing connections follow the assembly drawing.

When should I replace a filter bag in a valved duplex system?

Use the pressure drop across the operating vessel and the specified bag change-out or service limit. Dirt load, liquid and filter media affect bag life. Vessel working pressure and bag differential pressure are separate limits.

Request a Quote